Adeunis RF TWIMO ARF7581AA Benutzerhandbuch - Seite 12
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kontrolleinheit Adeunis RF TWIMO ARF7581AA herunter. Adeunis RF TWIMO ARF7581AA 16 Seiten. Rf modules starter kit
RX mode
First column : RX counter
Second column : sent frame counter (= received frames counter)
RXcnt : number of frame received
FrameLost : lost frame counter
The PER can deducted by : FrameLost / TXcnt
6.2.
«Received level» mode
The «received level mode allows to run a permanent test between :
•
Two Starter kits
•
One Starter kit (in RX mode) and a TWIMO module installed in another device.
TX Mode : send a frame every seconds
First column : TX counter
Second column : RSSI level of the received frames
RXcnt : number of frame received
TXcnt : number of frame emitted
The lost frames can be calculated by: TXcnt - RXcnt
The PER can deducted by : (TXcnt-RXcnt) / TXcnt
208474A_UG_Starter kit_TWIMO_V1.0
12