Adeunis RF TWIMO ARF7581AA 사용자 설명서 - 페이지 12
{카테고리_이름} Adeunis RF TWIMO ARF7581AA에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Adeunis RF TWIMO ARF7581AA 16 페이지. Rf modules starter kit
RX mode
First column : RX counter
Second column : sent frame counter (= received frames counter)
RXcnt : number of frame received
FrameLost : lost frame counter
The PER can deducted by : FrameLost / TXcnt
6.2.
«Received level» mode
The «received level mode allows to run a permanent test between :
•
Two Starter kits
•
One Starter kit (in RX mode) and a TWIMO module installed in another device.
TX Mode : send a frame every seconds
First column : TX counter
Second column : RSSI level of the received frames
RXcnt : number of frame received
TXcnt : number of frame emitted
The lost frames can be calculated by: TXcnt - RXcnt
The PER can deducted by : (TXcnt-RXcnt) / TXcnt
208474A_UG_Starter kit_TWIMO_V1.0
12