MAINTENANCE & ADJUSTMENTS
Tension Calibration Procedure
Step 1
Set the tension to 60 lbs. as indicated by the
linear scale and rotary knob. Place the string
on one end of a tension calibrator into a
string clamp and secure. Place string lo-
cated on the other end of the calibrator into
the string tensioner and apply tension. If the
brake lever releases before 60 lbs. or after
60 lbs., the tension head should be cali-
brated as follows.
Step 2
Loosen the 1.5 mm locking set screw (A)
located on the side of the latching block as
shown. The set screw is used to hold the
adjustment screw in place.
A
Step 3
If the lever releases before 60 lbs., using the
B
supplied L-shaped hex wrench, turn the
adjustment screw (B) located on the left side
of the latch block counter-clockwise to in-
crease the engagement of the brake release
latch with the brake lever. Repeat step 1 and
B
adjust until the correct tension is indicated
on the calibrator.
If the tension indicated in step 1 is greater
than 60 lbs., turn the adjustment screw
clockwise to reduce the engagement of the
brake release latch with the brake lever.
Repeat step 1 and adjust until the correct
tension is indicated on the calibrator.