ENGLISH
• If there is no oven beneath the hob insert
a dividing panel at a minimum distance
of 20 mm from the bottom of the hob.
• Do not use silicon sealant between the
appliance and the worktop. Avoid
installing the appliance next to doors
and under windows as hot cookware
may be knocked off the rings when doors
and windows are opened.
• Only an authorized service engineer can
install, connect or repair this appliance.
Use only original spare parts.
Electrical connection
• Before connecting, check that the
nominal voltage of the appliance stated
on the rating plate, corresponds to the
available supply voltage. Also, check the
power rating of the appliance and
ensure that the wire is suitably sized to
suit the appliance power rating (refer to
the "Technical information" chapter). The
rating plate is located on the lower
casing of the hob.
• The appliance is not provided with a
mains cable. Buy the right one from
specialized dealer. Single phase or two-
phase connection requires a mains cable
of minimum 70°C temperature stability.
Cable has been provided with end
sleeves. According to IEC regulations use
for one-phase connection: mains cable 3
x 4mm² and for two-phase connection:
Technical data
Rating Plate
Made in Germany
© Inter IKEA Systems B.V. 1999
702.228.18
IKEA of Sweden AB
21552
SE - 343 81 Älmhult
mains cable 4 x 2.5mm². Please respect
in first priority specific national
regulations.
• The appliance works perfectly on AC
230 V, AC 220 V~ or AC 240 V~ 50 Hz
electrical network.
• You must have the means for
disconnection incorporated in the fixed
wiring. Have the appliance connected to
the mains using a device that allows the
appliance to be disconnected from the
mains at all poles with a contact opening
width of at least 3 mm, eg. automatic line
protecting cut-out, earth leakage trips or
fuse.
• You must have the connection and the
connecting links carried out as shown in
the connection diagram (it is located on
the underneath surface of the casing of
the hob). The earth lead is connected to
terminal marked with the symbol and
must be longer than leads carrying
electric current. Tighten the terminal
screws securely! Finally, secure the
connecting cable with the mains cable
cleat and the covering closed by
pressing firmly (lock into place).
Warning! Once connected to the
mains supply check that all
cooking zones are ready for use
by briefly setting each to
maximum power.
Model DAGLIG Typ 60 HAD 56 AO 7,1kW
PNC 949 594 312 04 S NO ............... 220-240V AC 50-60 Hz
15
230 V
DGT