CORNING Centrix Jumper-Routing

1. Connect Jumpers

WARNING: Never look directly into the end of a fiber that may be
carrying laser light. Laser light can be invisible and can damage your
eyes. Viewing it directly does not cause pain. The iris of the eye will
not close involuntarily as when viewing a bright light. Consequently,
serious damage to the retina of the eye is possible. Should accidental
eye exposure to laser light be suspected, arrange for an eye
examination immediately.
• Make the connections in the first cassette as described in this section.
• Then route the jumpers as described in
• Lastly, make the connections in the second cassette following the
instructions in this section.
Step 1: If routing jumpers to an adjacent frame, start with the most densely
loaded frame (source frame). Pull module out to detent position
(Figure
TPA-4460
Step 2: Press buttons on each side of the cassette
handle.
TPA-4461
STANDARD RECOMMENDED PROCEDURE 003-960 | ISSUE 4 | OCTObER 2017 | PAGE 2 OF 18
1).
Press
buttons
Section 2
or
5
for your application.
(Figure 2)
Figure 1
and lower the
Figure 2