KitchenAid 9752043 Einbauanleitung - Seite 2
Blättern Sie online oder laden Sie pdf Einbauanleitung für Ranges KitchenAid 9752043 herunter. KitchenAid 9752043 5 Seiten. 30" (76.2 cm) electric range with self-cleaning thermal/convection oven
Before you start...
Your safety and the safety of others
are very important.
We have provided many important safety
messages in this manual and on your appliance.
Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards
that can kill or hurt you and others.
All safety messages will follow the safety alert
symbol and either the word "DANGER" or
"WARNING". These words mean:
DANGER
You can be killed or seriously injured if you
don't immediately follow instructions.
WARNING
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will tell you what the potential
hazard is, tell you how to reduce the chance of
injury, and tell you what can happen if the
instructions are not followed.
Read electrical and carpentry instructions.
Proper installation is your responsibility. A
qualified technician must install this range. Make
sure you have everything necessary for correct
installation. It is the customer's responsibility to
make sure that the countertop has been properly
prepared and that the installation clearances
specified on the model/serial rating plate are
met. The model/serial rating plate is located on
the oven frame behind the drawer.
Check location where range will be installed.
The range should be located for convenient use
in the kitchen. Recessed installations must
provide complete enclosure of the sides and rear
of range.
ALL OPENINGS IN THE WALL OR FLOOR
WHERE RANGE IS TO BE INSTALLED MUST
BE SEALED.
IMPORTANT: Some cabinet and building
materials are not designed to withstand the heat
produced by the oven for baking and self-
cleaning. Check with your builder or cabinet
supplier to make sure that the materials used
will not discolor, delaminate or sustain other
damage.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adiquate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest
edition*, or CSA Standard C22.1, Canadian
Electrical Code, Part 1 — latest edition**, and
all local codes and ordinances.
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280); or when such
standard is not applicable, the Standard for
Manufactured Homes Installations (Manufactured
Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A, or with local codes*.
In Canada, the installation of this range must
conform with the current standards
CAN/CSA-Z240 — latest edition**, or with local
codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any
method of securing the range is adequate as long
as it conforms to the standards listed above.
Four-wire power supply cable must be used in a
mobile home installation. The appliance wiring will
need to be revised. See four-wire electrical
connection, Panel B.
Copies of the standards listed may be obtained from:
*
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
**
Canadian Standard Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario M9W 1R3
Panel A
Cabinet opening dimensions
25" (63.5 cm) countertop depth and 24" (61 cm) base cabinet depth,
36" (91.4 cm) countertop height
Freestanding Range
13" (33 cm) max.
upper cabinet depth
30" (76.2 cm) min.
cabinet opening width
18" (45.7 cm)
upper cabinet
to countertop
30-1/4" (76.8 cm)
opening width
4" (10.2 cm)
min. clearance
from both sides
of range to side
wall or other
combustible
material.
7/8" (2.2 cm)
min. required
between cutout
and cabinet
door or hinge.
Important: Observe all governing codes and
ordinances.
When installing a range under existing cabinets
and the installation does not meet the minimum
cabinet clearances, install a range hood above
the cooktop to avoid burn hazards.
Grounded electrical outlet is required. See
"Electrical requirements," Panel B.
Cabinet opening dimensions that are shown
must be used. Given dimensions are minimum
clearances.
Do Not pinch the power supply cord between
the range and the wall.
Do Not seal range to side cabinets.
Slide-in ranges: countertop preparation
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish (flat) countertop
and the opening width is 30-3/8" (77.2 cm), no
countertop preparation is required.
Formed front-edged countertops: Must have
molded edge shaved flat 1/4" (0.64 cm) from
each front corner of opening.
Tile countertops may need trim cut back
1/4" (0.64 cm) from each front corner and/or
rounded edge flattened.
30-3/8"
(77.2 cm)
opening
width
30-7/8"
(78.4 cm)
Product dimensions
Freestanding Range
30"
8-1/4"
(76.2 cm)
(21 cm)
cooktop
width
1" (2.5 cm)
spacer
27-3/4"
(70.5 cm)
depth with
handle
For minimum
clearance to
the top of the
cooktop, see
Note.***
18" (45.7 cm)
upper cabinet
to countertop
4" (10.2 cm)
min. clearance
from both sides
of range to side
junction box –
wall or other
8" (20.3 cm) to
combustible
22" (55.9 cm) from
material.
either cabinet,
7" (17.8 cm) max.
from floor.
***
Note: 24" (61 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (0.64 cm)
flame retardant millboard covered with not less than
No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected
wood or metal cabinet.
Anti-tip bracket:
If countertop opening width is greater than
30-3/8" (77.2 cm), adjust the 1/4" (0.64 cm)
dimension.
Countertop must be level. Place level on
countertop, first side to side; then front to back. If
countertop is not level, range will not be level.
Oven must be level for satisfactory baking
conditions.
1/4"
(0.64 cm)
Formed or tiled countertop
trimmed 1/4" (0.64 cm)
back at front corners of
countertop opening.
1-1/2"
(3.8 cm)
44-3/8"
(112.7 cm)
overall
height
36" (91.4 cm)
cooktop
height with
feet loosened
1-1/2 turns
36" (91.4 cm)
cooktop
height with
feet loosened
1-1/2 turns
30"
(76.2 cm)
width
When installed in a 24"
(61 cm) base cabinet with
25" (63.5 cm) countertop —
front of oven door
protrudes 1-7/8" (4.8 cm)
beyond 24" (61 cm) base
cabinet.
Slide-in Range
13" (33 cm) max.
upper cabinet depth
30" (76.2 cm) min.
cabinet opening width
22-3/4" (57.8 cm)
opening depth
1/2" (1.3 cm)
radius both
corners
30-3/8" (77.2 cm)
opening width
junction box – 8" (20.3 cm) to
22" (55.9 cm) from either
cabinet, 7" (17.8 cm) max. from
floor.
7/8" (2.2 cm)
min. required
between cutout
and cabinet
door or hinge.
The floor anti-tip bracket
MUST be installed. To
install the anti-tip bracket
shipped with the range,
see Panel C and the
anti-tip bracket template.
22-5/8"
(57.5 cm)
Cooktop sides of range fit over
edges of countertop opening.
Slide-in Range
30"
(76.2 cm)
cooktop
width
22-5/8"
(57.5 cm)
1"
(2.5 cm)
25-3/4"
(65.4 cm)
depth with
handle
For minimum
clearance to
the top of the
cooktop, see
Note.***
30"
(76.2 cm)
width