KitchenAid 9752043 Einbauanleitung - Seite 3
Blättern Sie online oder laden Sie pdf Einbauanleitung für Ranges KitchenAid 9752043 herunter. KitchenAid 9752043 5 Seiten. 30" (76.2 cm) electric range with self-cleaning thermal/convection oven
Tools needed for
installation:
level
Phillips
flat-blade
screwdriver
screwdriver or
5/16" nut
driver
pliers
safety
glasses
wrench
hand or electric drill
wood floor: 1/8" drill bit
gloves
concrete/ceramic floor:
3/16" carbide-tipped
masonry drill bit
Parts supplied for
installation:
anti-tip
bracket
2 plastic
anchors
2 screws
(#10 x 1-1/2")
Electrical
requirements
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are not
sure range is grounded.
Do Not have a fuse in the neutral or
ground circuit.
When a four-wire or three-wire, single-
A.
phase, 120/240-volt, 60-Hz, AC-only,
electrical supply is available, a 50-ampere
maximum circuit protection is required, (or, if
specified on the model/serial rating plate, when a
four-wire or three-wire, single-phase 120/208-volt,
60 Hz, AC-only electrical supply is available, a 40-
ampere maximum circuit protection is required),
fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. The model/serial
rating plate is located on the oven frame behind the
drawer.
THE RANGE MUST BE CONNECTED
B.
WITH COPPER WIRE ONLY.
Wire sizes and connections must conform
C.
to the requirements of the National
Electrical Code, ANSI/NFPA 70 — latest
edition* or CSA Standard C22.1, Canadian
Electrical Code, Part 1 — latest edition** and all
local codes and ordinances for the kilowatt rating of
the range.
Copies of the standards listed may be obtained from:
*
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
**
Canadian Standard Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario M9W 1R3
Panel B
D.
non-metallic sheathed, copper cable (with
ground wire). Locate the junction box to allow
two to three feet of slack in the line so that the
range can be moved if servicing is ever
necessary. Do Not cut the conduit.
3/8"
ratchet
A U.L.-listed conduit connector must be provided
at each end of the power supply cable (at the
range and at the junction box). Wires sizes
(COPPER WIRE ONLY) and connections must
conform with the rating of the range.
Electrical
connection
hammer
measuring tape
or ruler
Turn power supply off before connecting
wires.
Use 8-gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
(Bracket must be
securely mounted to
sub-floor. Thickness
This range must be connected to a grounded,
of flooring may
metallic, permanent wiring system, or a
require longer
ground connector should be connected to
screws to anchor the
the ground terminal or wire lead on the
bracket to sub-floor.)
range.
This range is manufactured with white (neutral)
power supply wire and a cabinet-connected
green ground wire twisted together.
Connect the range cable to the junction box
through a U.L.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.
A. If connecting to a four-wire
electrical system...
Do Not connect the cabinet-grounding
conductor to the neutral (white) junction box
wire:
Figure 1
1. Disconnect the power supply.
2. Separate the green (or bare) and white
appliance cable wires.
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 1.
5. Connect the green appliance cablewire to the
green ground wire in the junction box.
This range should be connected
directly to the fused disconnect or circuit
breaker box through flexible, armored or
WARNING
Electrical Shock Hazard
cable from
junction
power supply
box
white
wires
red
wires
black
bare or
wires
green
wires
U.L.-listed
cable from
conduit
connector
range
B. Where local codes permit...
connecting the cabinet-grounding conductor
to the neutral (white) junction box wire:
cable from
power supply
junction
box
red
wires
white
wires
bare or
green wire
cable from
Figure 2
range
Grounded Neutral
1. Disconnect the power supply.
2. Remove the terminal block cover.
3.Connect together 3 wires: green and white
appliance cable wires and the neutral (white)
wire in junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 2.
C. Where local codes DO NOT
permit...
connecting the cabinet-grounding conductor
to the neutral (white) junction box wire.
Cable from
Junction
power supply
box
Red
wires
Bare or
green
U.L.-listed
wires
conduit
cable from
Figure 3
connector
range
Grounded Neutral
1. Disconnect the power supply.
2. Separate the green and white appliance cable
wires.
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 3.
5. Connect the green or bare ground wire from
the appliance cable to a grounded wire in the
junction box.
Now start...
With range in kitchen.
Put on safety glasses and gloves.
1.
Remove shipping materials, tape and
protective film from range. Keep
cardboard bottom and shipping base under
range. Remove oven racks and parts package
from inside oven.
2.
Take 4 cardboard
corners from the
carton. Stack one
cardboard corner
on top of another.
Repeat with the
other two
corners. Place
spacers
corners lengthwise
on the floor in back of range so corners will
support outer side edges of range as shown.
black
wires
U.L.-listed
conduit
connector
White
wires
Black wires
cardboard
corners