Garmin GSD 26 Installationsanleitung Handbuch - Seite 3

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Schiffsausrüstung Garmin GSD 26 herunter. Garmin GSD 26 6 Seiten. Professional sonar module
Auch für Garmin GSD 26: Installationsanleitung Handbuch (6 seiten), Installationsanleitung Handbuch (14 seiten)

Garmin GSD 26 Installationsanleitung Handbuch
3
Replace and secure the terminal block lid on the sounder
with a #2 Phillips screwdriver.
NOTE: The sounder does not operate when the lid is
removed.
Grounding the Sounder
The chassis ground post is located on the exterior of the
chassis, adjacent to a corner mounting hole.
1
Connect the chassis ground post to the boat water ground
circuit.
2
Mount the sounder
(Mounting the
power, marine network, transducer, and sensors
the
Sounder) .
Installing Locking Rings on the Cables
Before you install locking rings on the cables, you must route
the cables.
To help make the cable-routing process easier, the locking rings
are packaged separately from the cables. Each locking ring is
packaged in a small bag with a number on the label for easy
identification.
1
Separate the two halves of the locking ring
2
Align the two halves
snap them together.
3
Insert the o-ring
into the end of the connector.
Transducer Wiring Diagrams
Connecting the high-frequency wires to the low-frequency
terminal block, or the low-frequency wires to the high-frequency
terminal block, damages the device and the transducer.
You can use these diagrams to identify the connection points for
your transducer wires on the GSD 26 terminal block. Locate
your CHIRP/spread spectrum transducer model in the wiring
Sounder) and connect the
(Connecting
.
of the locking ring over the cable and
NOTICE
color tables
(Transducer Wire Color
information.
The outer shield wire must connect to one of the two screw
posts below the terminal block using the included ring crimp
terminal. When connecting two single-element transducers, you
must connect the second transducer to the duplicate set of
connections on the right side of the terminal block.
TIP: The primary transducer cable wire housing covers the
wiring bundles. To identify the wiring groups in the bundles more
easily, you can remove up to an inch of the cable housing.
Single-Element CHIRP/Spread Spectrum
Dual-Element CHIRP/Spread Spectrum with
Temperature and XID
NOTE: The temperature and XID wires can be connected at
either location.
Dual-Element CHIRP/Spread Spectrum with XID
NOTE: The XID wires can be connected at either location.
Dual-Element CHIRP/Spread Spectrum with Separate
Temperature Sensor
NOTE: The temperature and XID wires can be connected at
either location.
Tables) for more