Ê Reinstall the air duct (see the
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.6

Replacing the power-distribution module

The power-distribution module comprises a power backplane and a housing. In
case of a defect, you must replace the complete unit.
Removing the defective power-distribution module
Ê Remove the power supply unit(s) before you pull the server out of the rack.
Ê Open the server as described in the
page
23.
Ê Disconnect the power cables of the power-distribution module from the HDD
backplane and the system board (see the cabling plans in the Appendix of
the Options Guide).
Figure 15: Removing the power-distribution module
Ê Remove the two screws (see circles).
RX200 S6
section "Installing the air duct" on page
section "Opening/closing the server" on
Service Supplement
Replacement routines
A
A
26).
35