Fujitsu SPARC Enterprise M5000 Ergänzendes Handbuch - Seite 26

Blättern Sie online oder laden Sie pdf Ergänzendes Handbuch für Server Fujitsu SPARC Enterprise M5000 herunter. Fujitsu SPARC Enterprise M5000 36 Seiten. Rci build procedure
Auch für Fujitsu SPARC Enterprise M5000: Merkmale Handbuch (30 seiten), Produkthinweise (44 seiten), Handbuch "Erste Schritte (4 seiten)

Fujitsu SPARC Enterprise M5000 Ergänzendes Handbuch
CHAPTER 1 RCI Build Procedure
1.3.3

When an RCI I/O unit is added later

1
Connect the I/O unit to be added with an RCI cable by using a daisy-chain
connection (see
Connect an RCI branching connector to the RCI port, and then connect it with an RCI
cable by using a daisy-chain connection.
Connect an RCI terminating resistor to the branching connector at either end of the
RCI connection. Refer to
2
Turn on the AC input to all the units which are in the RCI connection.
3
Log in to the XSCF Shell.
4
Execute the setrci -c addconfig command to configure the RCI.
XSCF> setrci -c addconfig
The command completed successfully
5
Execute the setrci -c stat command to display the RCI status.
XSCF> setrci -c stat
HOST
address 000101ff
Active
LIST
address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out
000101ff OFF - ACT --
003001ff OFF - ACT --
003002ff OFF - ACT --
The command completed successfully
6
Verify that the added I/O unit is incorporated.
1-8
RCI Host

Figure 1.7 When an RCI I/O unit is added later

Figure
1.7).
Section 1.3.5, "Connection of RCI."
Addition
RCI I/O unit
RCI I/O unit
host 0001 0a
disk 0400 04
disk 0400 04
-
-
-
C120-E361-04EN