Fujitsu ETERNUS DX200 S3 Konfigurationshandbuch Serververbindung - Seite 9

Blättern Sie online oder laden Sie pdf Konfigurationshandbuch Serververbindung für Lagerung Fujitsu ETERNUS DX200 S3 herunter. Fujitsu ETERNUS DX200 S3 12 Seiten. Hybrid storage systems, all-flash arrays, power synchronized unit
Auch für Fujitsu ETERNUS DX200 S3: Konfigurationshandbuch Serververbindung (12 seiten), Konfigurationshandbuch (28 seiten), Konfigurationshandbuch (13 seiten), Konfigurationshandbuch (18 seiten), Setup-Handbuch (15 seiten), Sicherheitsvorkehrungen (12 seiten)

Fujitsu ETERNUS DX200 S3 Konfigurationshandbuch Serververbindung
Chapter 2
Setting Up the ETERNUS DX
2.1
Common Settings
2.1.3

Setting the Host Responses

The host response parameters for the ETERNUS DX must be set to match the way the server processes the
responses to requests from the ETERNUS DX. Setting the host response must be done before connecting the
ETERNUS DX to the server.
Set the parameters that are described below for each OS.
Retain the default values for all of the parameters that are not described below.
Table 2.2 Host response settings
OS
Solaris
®
Windows
VMware ESX
Linux
2.1.4

Setting the CA Port Groups

Create new SAS port groups and register the ports as members of the groups. A SAS port group is a group of
SAS-CA type ports that are connected to the specified host group. Configure the host affinity setting for each
SAS port group.
2.1.5

Registering the SAS Addresses of the Accessing SAS Cards (Setting SAS Host)

Register the SAS addresses of the SAS cards installed in each server that will access the ETERNUS DX. At the
same time, set the host response registered in
SAS hosts (SAS addresses).
Registering the SAS hosts (SAS addresses) and setting up Host Affinities as described elsewhere, allows limits
to be set on which servers are allowed to access which ETERNUS DX storage systems.
When a server-side SAS card is replaced, the SAS address of the replacement SAS card must be re-regis-
tered to the ETERNUS DX.
1
Connect the SAS card that is installed in the server to the ETERNUS DX with the SAS cable.
2
Turn on the ETERNUS DX.
3
Turn on the server, and start the OS.
4
Acquire the SAS address of HBA from each port in the [Setup SAS Host] screen of ETERNUS Web GUI.
Conditions
When using the OS standard
Multipath Driver (MPxIO)
Other cases
For SUSE Linux Enterprise
Server 10
Other cases
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
Copyright 2014 FUJITSU LIMITED
Host response selec-
Parameter
tion
Solaris MPxIO
Default
Default
None
Sense Data Conversion
(Create a new host re-
sponse)
Default
"2.1.3 Setting the Host Responses" (page 9)
9
Setting value
b/c1/01 g 6/c1/01
to accept these
P3AM-8542-04ENZ0