Connectors and indicators
The LEDs have the following meaning:
LED
A - GEL
(Global Error
LED)
B - CSS
(Customer Self
Service)
C - Identification Blue on
D1 - board
D2 - board
D3 - board
D4 - board
E1 - overall
memory
E2 - memory
F - system
fans
32
Indicator
Meaning
Off
No error (non CSS component)
Orange on
Indicates a prefailure (non CSS
component)
Orange
Indicates a failure. Reasons for a failure
flashing
may be:
– a sensor detects an error
– sensor defect
– fan defect
– CPU error
– Software detected an error
Off
No error (CSS component)
Yellow on
Indicates a prefailure (CSS component)
Yellow flashing Indicates a failure (CSS component)
Server is identified via the ServerView
Operations Manager
Blue flashing
Local monitor off via AVR
Yellow on
AUX voltage available
Green on
System running
Red on
Configuration error.
The system board will be held in reset.
Possible configuration errors are e.g.: old
CPU populated, CPUs with different FSB
requirements populated, CPU1 not
populated.
Green flashing iRMC S2 ok
On / off
iRMC S2 inactive
Off
All memory modules running
Orange on
At least one memory module defective
Off
Memory module running
Orange on
Memory module failure
Off
Fan running
Orange on
Fan failure
Technical Manual
D2799 (TX200 S6)