Mechanics
USB power jumper function
description
Pin
1
2
3
Jumper 2-3
Jumper 1-2

BIOS options

Please refer to BIOS description on the including CD-ROM (menu Advanced System Management ).

Messages

The Message LED (frontpanel connector) shows two different states:
A slow blinking (once a second) of the LED signals that any application has received a
message. (ACPI- mode)
A fast blinking (five times a second) of the LED signals a hardware problem.
The fast blinking LED can have several different causes:
a necessary sensor is missing or defect
an available sensor has overtemperature
a fan is defect or not working properly
a software is responsible for blinking
More detailed information are shown with an additional System Monitoring Software or on
i
the monitor after reboot entering BIOS Setup (menu Advanced System Management ).
BIOS: Please refer to BIOS description on the including CD-ROM.
12
Default setting:
If the power supply supports auxiliary voltage the USB interface is
permanently powered except when the main supply is plugged off.
Wakeup from ACPI S1-S4 state possible.
The USB interface is only powered in operating state.
Wakeup from ACPI S1 state possible.
Signal
VCC
USB power connection
VCC_AUX
1
A26361-D1160-Z180-5-7619