Indesit RID60G2/UK Betriebsanleitung - Seite 4

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Herde Indesit RID60G2/UK herunter. Indesit RID60G2/UK 24 Seiten. Free standing gas cooker

Indesit RID60G2/UK Betriebsanleitung
Installation
GB
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure)
and the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated on
the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should
be given to the relevant requirements regarding
ventilation.
MODEL NUMBERS ID60G1; ID60G2
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20)
at 20 mbar but can be converted for use on BUTANE
(G30) at 28-30mbar or PROPANE (G31) at 37mbar with
the use of the LPG conversion kit that can be obtained
free of charge, if you contact our Genuine Parts and
Accessories department (see Key Contacts, back
page).
GAS SAFETY (INSTALLATION & USE)
REGULATIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the
law. In the UK,gas safe registered installers work to
safe standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to install
the cooker correctly could invalidate the warranty
liability claims and could lead to prosecution.
LOCATION
The cooker may be located in a kitchen, kitchen/diner
Burner
Hotplate
Front Left
Hotplate
Rear Left and Rear Right
Hotplate
Front Right
Grill
Main Oven
Top Oven
4
or a bed-sitting room, but not in a room containing a
bath or shower. The cooker must not be installed in a
bed-sitting room of less than 20m
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air
supply in accordance with BS 5440: Part 2.
The room must have an opening window or equivalent;
some rooms may also require a permanent vent. If the
room has a volume between 5 and 10m
an air vent of 50cm
door which opens directly to outside. If the room has
a volume of less than 5m
100cm
appliances in the same room, BS 5440: Part 2 should
be consulted to determine air vent requirements.
TECHNICAL DATA
Gas connection
Pressure test point
injector
Gas rate adjustment
Aeration adjustment
Electrical connection
G20 at 20mbar
Heat Input
Injector
3.0 kW
116
2.0 kW
103
1.1 kW
79
3.7 kW
150 (X)
2.5 kW
115
1.9 kW
100
effective area unless it has a
2
, it will require an air vent of
3
effective area. If there are other fuel burning
2
Rp ½ (½" BSP female)
None
None
Flexible cord fitted with a
13A fuse.
G30 at 28-30mbar
G31 at 37mbar
Heat Input
3.0 kW (218g/h)
2.0 kW (145g/h)
1.0 kW (73g/h)
3.4 kW (243g/h)
2.3 kW (167g/h)
1.9 kW (138g/h)
.
3
, it will require
3
Front left hotplate
3 pin 13 amp plug
230/240V a.c. 50x60 Hz.
Injector
86
70
50
91
71
66