AEG protect d. 2000 Installations- und Betriebsanleitung - Seite 5

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Lüftungshaube AEG protect d. 2000 herunter. AEG protect d. 2000 25 Seiten. Fume extractor hood

Electrical connections

Electrical connections
Electrical connections
Electrical connections
Electrical connections

Safety warnings for electrician

Safety warnings for electrician
Safety warnings for electrician
Safety warnings for electrician
Safety warnings for electrician
Check that the power supply voltage shown on the rating
plate corresponds to the mains supply before proceeding
to make any electrical connections. If the unit is supplied
ready-fitted with a plug, it can be connected to any easily
accessible socket installed in compliance with the
regulations in force.
If a fixed connection is required, the hood must be
installed exclusively by an electrician registered with the
local electrical company. The hood should be installed
using an omnipolar switch with contacts that open to at
least 3 mm.
Fused switches can be used for this purpose (with
cartridge fuses that can be extracted from the fuse
holder), as can automatic circuit breakers and contactors
which open to more than 3 mm.
We decline all responsibility for any problems or faults
caused by a failure to observe the above instructions.
If the power socket is positioned directly above the
extractor hood or on the chimney cover this will give two
advantages:
1. The socket cannot be seen.
2. The unit can be disconnected whenever required by
simply taking out the plug.
Electrical connections
Electrical connections
Electrical connections
Electrical connections
Electrical connections
220-230 V - using fixed power supply line with plug.
(The unit should only be connected up by an authorized
electrician).
30