To elevate water level: Rotate screw
clockwise and raise float to the desired
water level. Elevate water cup to a
proper position as well. (Refer to float
adjustment instructions.)
Fasten the snap along "CLOSE"
direction.
Float adjustment instructions: Make
sure the height of surface E is 2-4mm
lower than surface G.
1259054-T01-A
Fig.#15c
15c
SCALE
5:1
Fig.#15d
15d
E
Float
Water Cup
Fig.#15e
15e
-7-
CLOSE
Screw
E
G 2-4mm