Kohler ADAIR K-4983T-M Manuale di istruzioni per l'installazione - Pagina 7
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Servizi igienici Kohler ADAIR K-4983T-M. Kohler ADAIR K-4983T-M 9. 4.2l skirted class five+ one-piece toilet, s-trap 305/400mm
To elevate water level: Rotate screw
clockwise and raise float to the desired
water level. Elevate water cup to a
proper position as well. (Refer to float
adjustment instructions.)
Fasten the snap along "CLOSE"
direction.
Float adjustment instructions: Make
sure the height of surface E is 2-4mm
lower than surface G.
1259054-T01-A
Fig.#15c
15c
SCALE
5:1
Fig.#15d
15d
E
Float
Water Cup
Fig.#15e
15e
-7-
CLOSE
Screw
E
G 2-4mm
G