#10 x 1-1/4"
Screw
End Cap
6. Attach End Caps
- Locate the spacer blocks and hardware bag.
- Using a piece of masking tape, tape the spacer blocks in location on the outside of the cabinets. Make sure the
pilot holes line up with the recommended holes in the mirror cabinet.
- Position the end caps so the beveled edges are toward the mirror and the front of the cabinet. Align the end caps
so that they are centered to mirror height. End caps should be flush with back of cabinet. Hold or clamp carefully
(protect the surface if clamping) until attachment screws are in place.
- Partially drive four #10 x 1 1/4" screws (provided) through the inside location holes, through spacer block holes
and into the end cap. Tighten screws to secure end cap.
- Place dome cap covers over the screw heads.
7. Attach the Door
- Re attach the door.
- The door is provided with a three way adjustment feature for alignment. Height, level, and fit to the frame gasket
can be adjusted. The use of #2 Phillips screwdriver is recommended.
- If the door is out of level or too close to one side adjust the door left or right with screw #1.
- If the door is too high or too low adjust it up or down with screw #2.
- If the door opens swiftly, squeaks or rubs against the gasket, adjust the door outward with screw #3 .
- Check the door swing. The hinges are provided with a 110 degree black plastic stop to restrict door from swinging
wide.
A
1010988-2-
Dome Cap Cover
End Cap
Spacer Block
Screw #3
Hinge Adjustment
8
Screw #1
Screw #2
Kohler Co.