Aqua Invent AH-18 Duplex Installation und Inbetriebnahme - Seite 3
Blättern Sie online oder laden Sie pdf Installation und Inbetriebnahme für Wasserspender Aqua Invent AH-18 Duplex herunter. Aqua Invent AH-18 Duplex 8 Seiten. Twin-tank water softener
Drain connection
Connect To drain
Connection For
Brine hose
Bypass-valve
Fig 2. Backside of Filter valve 9100 SE
1. Place the softener tanks where you want to install the unit.
NOTE: Be sure the tanks are in level and on a firm base.
2. Make the connection between tank 1 and tank 2 with delivered interconnection
pipes. Lubricate the O-rings with silicon grease and push gently the pipes into
the filter valve respectively the "tank 2 adapter". Push the plastic yokes against
the valve respectively the adapter and secure them with the metal clip.
3. Adapt the bypass valve to the filter valve by gently pushing it into the filter valve
and secure with the metal clip.
4. Connect incoming and outgoing water lines to the bypass valve (be aware of flow
direction, marked with arrows). Perform all plumbing according to local plumbing
codes.
It is recommended to install a T-piece with sample valve in the outgoing water
line (this gives the possibility to make water tests with the delivered "hardness
test kit").
Use minimum a ½'' hose for the drain (included in delivery). Never connect
-
filter valve drain line with brine-tank overflow fitting!
5. Be sure the floor under the brine tank is clean and in level.
6. Connect brine tank and filter valve with delivered 3/8'' PEH hose.
7. Place the bypass valve in Bypass position.
Turn on the main water supply.
-
Open a cold soft water tap nearby and let water run a few minutes or until
-
the system is free of foreign material (usually solder) resulting from the
installation. Close the water tap when water runs clean.
Aqua Invent AB – AH-18 Duplex – 2019-10
Metal Clip
Tank 1
Interconnection pipes
Tank 2
"tank 2 adapter"