CPS Compute-A-Charge CC220E Benutzerhandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Skalen CPS Compute-A-Charge CC220E herunter. CPS Compute-A-Charge CC220E 8 Seiten. Refrigerant charging scale

LCD DISPLAY ABBREVIATIONS

MODES TO
SELECT
WHEN IN
CHARGE MODE
WHEN IN
RECOVER MODE
WHEN IN
CHARGE OR
RECOVER MODE
WHEN IN ANY
MODE

SCALE SETUP

A. Remove scale from storage case and place on level, rigid surface.
B. Install one or two (included) 9V batteries in back of control.
C. Press power (icon) to turn scale ON.
D. APO (Automatic Power Off). 5 minutes = default setting [you may also select 10, 15, 30, 60
mins, or turn APO OFF].
E. DISPLAY RESOLUTION: Default is 0.2 Oz (5g). Press
found. Press
F. WEIGHT UNITS: Press
SCALE (WEIGH) MODE ("SCL")
1. Place refrigerant tank on scale
2. Default mode is "SCL" (weigh).
3. View GROSS weight on display.
4. Remove tank from platform after weight observed.
5. Display will flash if maximum weight capacity (220 Lb/100 kg) exceeded.
CHARGE MODE ("CHg")
1. Place refrigerant tank on scale
2. Connect equipment per DIAGRAM A (CHARGE).
3. Press
CHARGE "Chg".
4. Use
amount to be tracked), then press
5. Once tank and manifold valves are opened, the charge
(tracking) session will begin. The display will show a
small "c" indicating"charge" and how much refrigerant
has been charged into your system (removed from the
refrigerant tank).
6. During charging, screen characters will eventually flash
at an increasing rate, showing that the programmed
charge amount is closer to being reached.
• HOLD - Pressing
tighten hoses, change tanks if necessary, but continue later without losing track of the NET
amount charged.
• SET/RESET - Pressing
being tracked. The normal WEIGH Mode will resume.
• GO/HOLD - After any adjustments are made, the accumulated amount being tracked
1.800.561.8187
SCL= Scale
CHg = Charge
c = Charge (track-
F = Final programmed charge
ing) in process
achieved
t OFF: Ensure tank
t ON: Place tank ON scale
NOT on scale
h = Hold (pause) refrigerant tracking
OL= Overload (Reduce load immediately)
to select. See specifications table for other selectable values.
to select.
to scroll through the menu and choose
to input desired weight (charge
while charging will PAUSE charge tracking, allowing the user
during charge operation will stop/cancel the charge from
• NOTE: So that the actual charged vs. tracked amounts align, remember to physically
stop charging by closing tank and/or manifold valves before pressing HOLD.
can be resumed by pressing
www.
DISPLAY ABBREVIATIONS
rEC = Recover rES = Resolution
r = Recovery
(tracking) in
process
until desired value
DIAGRAM A (CHARGE)
.
.com
APO = Auto-
matic Power OFF
n = Net gain
o = Tank
of one or more
overfilled
tanks
5