Avtron AV85 Anleitung Handbuch - Seite 9

Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Medienkonverter Avtron AV85 herunter. Avtron AV85 10 Seiten. 8 1/2 inch c-face mount modular

Avtron AV85 Anleitung Handbuch
THIN-LINE II™ and III™

Application Examples

Applies to all AV85 models, except, wiring options "A", "B", "C", "D", "G", "Q", "R", "S", "T" and "U".
Avtron THIN-LINE II & III encoders provide an alarm signal if maintenance is required under specific circumstances. An
alarm LED indicator is also available. Green indicates power on, red or orange indicates alarm on. Following are application
examples provided to help install the alarm output.
Example 1. Alarm output using +V(OUT). +V(OUT) is equal to +V, the encoder power supply.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
Q5
MMFT6661
Example 2. Alarm Output Using Separate 24 VDC Power Supply and Relay.
ENCODER
FUNCTIONAL DIAGRAM
LINE
DRIVER
NOTE 1
Q5
MMFT6661
ALARM OUTPUT CONNECTION
OUTPUT OPTIONS
"L","W"
"P","Z"
{
1
BLACK
6
RED
CR8
GREEN
2
YELLOW
7
3
BLUE
8
GRAY
4
ORANGE
9
WHITE
5
BROWN
VIOLET
10
OUTPUT OPTIONS
"L","W"
"P","Z"
{
BLACK
1
6
RED
CR8
2
GREEN
7
YELLOW
3
BLUE
8
GRAY
4
ORANGE
9
WHITE
5
BROWN
10
VIOLET
AV85
FUNCTION
COMMON
+V (Encoder Power)
ØA
ØA
ØB
ØB
MARKER
MARKER COMPLEMENT
50 mA MAXIMUM
300 OHM
MIN.
GND
4-16 VDC SOLID STATE RELAY
FUNCTION
COMMON
+V (Encoder Power)
ØA
ØA
POWER
SUPPLY
ØB
ØB
MARKER
MARKER COMPLEMENT
SINK 100 mA MAXIMUM,
WITHSTAND 50 V MAXIMUM
GND
REFERENCED TO COMMON
9
Vcc
OUT
COM
-
24
115 VAC
VDC
+
RELAY