Installing a Server Module
Slide the server module into the chassis until it stops.
1
Rotate the server module's handle up to fully seat the server module. See Figure 1-2.
2
Using a#2 Phillips screwdriver, tighten the captive screw that secure the handle to the
3
front of the server module. See Figure 1-2.
The server module board upgrade is complete.
If the server module was configured with one hard drive or two hard drives in
4
nonmirrored mode or the server module was configured in mirrored mode and the
message Logical drive optimal was displayed, go to "Verifying the System
Setup Options."
If the server module was configured in mirrored mode and the message Logical
drive resynchronizing was displayed, go to "Manually Configuring the
Mirroring Mode."
Verifying the System Setup Options
NOTE: If you are using the PERC 4/im DOS Utility diskette, go to "Running the PERC
4/im DOS Utility." If only one drive or two drives are installed in nonmirrored mode,
go to step 1.
Turn on the server module. See Figure 1-1.
1
If the server module does not turn on, see "Getting Help" in your Installation and
Troubleshooting Guide.
Enter the System Setup program.
2
Ensure that the processor, memory, and service tag information is correct.
3
The service tag should match the service tag written on the server module's handle.
If the service tag information is not correct, see "Programming the Service Tag."
Press <Esc> to exit the System Setup program.
4
NOTE: The server module upgrade is complete if only one hard drive was installed or if
there were two hard drives installed without the mirror mode enabled.
Re plac ing the Se r ve r Mo dule Bo ard