8 Additional Information
•
Non-Dell drive lock-out – In order to ensure the highest quality products and best customer
experience, the PERC H800 will not allow for non-Dell™ SAS HDDs or SSDs to be initialized or
configured in a Dell™ PowerVault™ MD1200 or MD1220.
•
Backward Compatibility (MD1200) - The PowerVault™ MD1200 does not provide backward
compatible support for connecting to previous generation adapters (PERC 5/E or PERC 6/E) or
daisy-chaining with previous generation enclosures (MD1000, MD1120, MD3000, MD3000i).
MD1200 does support a drive carrier that is common with the Dell™ 11
servers.
The previous generation PowerVault™ MD1000 carrier is not compatible with the
MD1200.
•
Backward Compatibility (MD1220) - The PowerVault™ MD1220 does not provide backward
compatible support for connecting to previous generation adapters (PERC 5/E or PERC 6/E) or
daisy-chaining with previous generation enclosures (MD1000, MD1120, MD3000, MD3000i).
MD1220 supports a drive carrier that is common with the Dell™ 11
servers and the previous generation PowerVault™ MD1120.
•
Enclosure Migration and Drive Format – The PowerVault™ MD1200 and MD1220 will not be
supported behind Dell's 3Gb/s PowerVault™ External RAID enclosures, MD3000 and MD3000i.
•
Audible alarm – The PowerVault™ MD1200 and MD1220 support an audible alarm within the
enclosure (must be enabled via OMSS / PERC H800).
•
EMM blank – An EMM blank must be installed in EMM1 position if a second EMM is not installed.
This is required for proper airflow. In order to remove the EMM blank; you will need to remove
EMM0 to access a release latch (see Figure 14) for blank. This ensures the customer shuts down
the enclosure before making any configuration changes that could but data at risk.
** Available in Q3 2010
Figure 14. Latch
th
Generation PowerEdge™
th
Generation PowerEdge™
The
23