Dell Storage Center SCv2020 Handbuch "Erste Schritte - Seite 18

Blättern Sie online oder laden Sie pdf Handbuch "Erste Schritte für Lagerung Dell Storage Center SCv2020 herunter. Dell Storage Center SCv2020 19 Seiten. Storage center
Auch für Dell Storage Center SCv2020: Benutzerhandbuch (42 seiten), Handbuch "Erste Schritte (20 seiten)

Dell Storage Center SCv2020 Handbuch
Environmental
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
18
–40°C to 65°C (–40°F to 149°F) at a maximum altitude of
12,000 m (39,370 ft)
10% to 80% (noncondensing) with 29°C (84.2°F) maximum
dew point
5% to 95% (noncondensing) with 33°C (91°F) maximum dew
point
0.21 G at 5–500 Hz for 15 min
1.04 G at 2–200 Hz for 15 min
Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/-
10% (in operational orientations only)
Half-sine shock 30 G +/- 5% with a pulse duration of 10 ms
+/- 10% (all sides)
0 m to 3,048 m (0 ft to 10,000 ft)
–300 m to 12,000 m (–1000 ft to 39,370ft)
G1 or lower as defined by ISA-S71.04-1985