Environmental
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
18
–40°C to 65°C (–40°F to 149°F) at a maximum altitude of
12,000 m (39,370 ft)
10% to 80% (noncondensing) with 29°C (84.2°F) maximum
dew point
5% to 95% (noncondensing) with 33°C (91°F) maximum dew
point
0.21 G at 5–500 Hz for 15 min
1.04 G at 2–200 Hz for 15 min
Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/-
10% (in operational orientations only)
Half-sine shock 30 G +/- 5% with a pulse duration of 10 ms
+/- 10% (all sides)
0 m to 3,048 m (0 ft to 10,000 ft)
–300 m to 12,000 m (–1000 ft to 39,370ft)
G1 or lower as defined by ISA-S71.04-1985