Dell Storage Center SCv2020 Başlangıç Kılavuzu - Sayfa 18

Depolama Dell Storage Center SCv2020 için çevrimiçi göz atın veya pdf Başlangıç Kılavuzu indirin. Dell Storage Center SCv2020 19 sayfaları. Storage center
Ayrıca Dell Storage Center SCv2020 için: Kullanıcı El Kitabı (42 sayfalar), Başlangıç Kılavuzu (20 sayfalar)

Dell Storage Center SCv2020 Başlangıç Kılavuzu
Environmental
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
18
–40°C to 65°C (–40°F to 149°F) at a maximum altitude of
12,000 m (39,370 ft)
10% to 80% (noncondensing) with 29°C (84.2°F) maximum
dew point
5% to 95% (noncondensing) with 33°C (91°F) maximum dew
point
0.21 G at 5–500 Hz for 15 min
1.04 G at 2–200 Hz for 15 min
Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/-
10% (in operational orientations only)
Half-sine shock 30 G +/- 5% with a pulse duration of 10 ms
+/- 10% (all sides)
0 m to 3,048 m (0 ft to 10,000 ft)
–300 m to 12,000 m (–1000 ft to 39,370ft)
G1 or lower as defined by ISA-S71.04-1985