3

Configure UPM ports as Ethernet pass-through (optional)

The FC ports on the Unified Port Module (UPM) can be configured as Ethernet pass-through. Use this
section only if the UPM module is used. The 12 ports are divided into six port groups numbered 0-5. Two
ports in each port group can be configured separately as FC or Ethernet pass-through.
Note: This operation requires a reload for the changes to take effect.
3.1

View the current configuration

Use this command to view the current mode of the ports and also the port group mapping.
FTOS#
show system
PortGroupId
0
1
2
3
4
5
3.2

Configure port group 0 as Ethernet pass-through

FTOS(conf)# stack-unit 0 port-group 0 portmode Ethernet
Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1
obsolete after a save and reload.
[confirm yes/no]:yes
Please save and reload for the changes to take effect.
Note: Save and reload is required.
10
SCG2004
Dell Networking S5000 Switch Configuration Guide for SC Series SANs
stack-unit
0 port-group portmode
Ports
Mode(Curr Boot) Mode(Next Boot)
0,1
FC
2,3
FC
4,5
FC
6,7
FC
8,9
FC
10,11
FC
FC
FC
FC
FC
FC
FC