Figure 1-5. Brackets for Rack Installation

Install the cage nuts onto the mounting rails of your rack, if your rack requires them.
2
NOTE:
Additional screws are provided for racks that have threaded mounting holes.
Position the switch in the rack and align the holes in the mounting bracket with the holes in
3
the rack.
Insert and tighten two screws appropriate for your rack through each of the mounting
4
brackets.

Installing the Switch on a Wall

To mount the switch on a wall, complete the following steps:
Ensure that the mounting point meets the following requirements:
1
The wall surface must be capable of supporting the switch.
Allow at least 5.1 cm (2 inches) on each side for proper ventilation and 12.7 cm (5 inches)
at the back for power cable clearance.
The location must not be located in direct sunlight.
The location must not be within 2 feet of any heating vents, nor should any area heating
vent point toward the unit.
The location must be ventilated to prevent heat buildup.
Do not locate the switch where there may be data or electrical cabling located directly
behind the unit.
The power cable must reach an outlet.
Use the supplied screws to attach a mounting bracket to each side of the switch (see
2
Figure 1-6).
11