Figure 1-5. Brackets for Rack Installation
Install the cage nuts onto the mounting rails of your rack, if your rack requires them.
2
NOTE:
Additional screws are provided for racks that have threaded mounting holes.
Position the switch in the rack and align the holes in the mounting bracket with the holes in
3
the rack.
Insert and tighten two screws appropriate for your rack through each of the mounting
4
brackets.
Installing the Switch on a Wall
To mount the switch on a wall, complete the following steps:
Ensure that the mounting point meets the following requirements:
1
•
The wall surface must be capable of supporting the switch.
•
Allow at least 5.1 cm (2 inches) on each side for proper ventilation and 12.7 cm (5 inches)
at the back for power cable clearance.
•
The location must not be located in direct sunlight.
•
The location must not be within 2 feet of any heating vents, nor should any area heating
vent point toward the unit.
•
The location must be ventilated to prevent heat buildup.
•
Do not locate the switch where there may be data or electrical cabling located directly
behind the unit.
•
The power cable must reach an outlet.
Use the supplied screws to attach a mounting bracket to each side of the switch (see
2
Figure 1-6).