Dell PowerEdge M610x Handbuch "Erste Schritte - Seite 10

Blättern Sie online oder laden Sie pdf Handbuch "Erste Schritte für Schalter Dell PowerEdge M610x herunter. Dell PowerEdge M610x 14 Seiten. Dell poweredge blade servers getting started guide
Auch für Dell PowerEdge M610x: Handbuch aktualisieren (44 seiten), Handbuch aktualisieren (21 seiten), Handbuch aktualisieren (14 seiten), Installationshandbuch (7 seiten), Handbuch "Erste Schritte (12 seiten), Handbuch "Erste Schritte (12 seiten), Portfolio-Handbuch (27 seiten), Technisches Handbuch (48 seiten), Handbuch "Erste Schritte (12 seiten)

Dell PowerEdge M610x Handbuch
Power — Enclosure
Heat dissipation
NOTE: Heat dissipation is calculated using the
power supply wattage rating.
Maximum inrush current
System Voltage Requirements
NOTE: This system is also designed to be connected to
IT power systems with a phase to phase voltage not
exceeding 230 V.
DC/DC power supply (per power supply module)
Wattage
Connector
Heat dissipation
Maximum inrush current
System Voltage Requirements
NOTE: Heat dissipation is calculated using the power
supply wattage rating.
Physical — Blades
PowerEdge M915
Height
Width
Depth
Weight (maximum)
PowerEdge M910
Height
Width
Depth
Weight (maximum)
PowerEdge M820
Height
Width
10
1200 BTU/hr (maximum)
Under typical input voltage conditions and over the
entire system ambient operating range, the inrush
current may reach 55 A per power supply for 10 ms or
less.
16 A, 200 V AC to 240 V AC, 50 Hz/60 Hz (3000 W power
supply)
16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz (2700 W power
supply)
2700 W
Molex # 394260002 at PSU end,
mating connector Molex # 39422-0012
1205 BTU/hr (maximum)
Under typical input voltage conditions and over the
entire system ambient operating range, the inrush
current may reach 120 A per power supply for 10 ms or
less.
75 A, 48 V DC to 60 V DC
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
12.7 kg (28 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
13.1 kg (29 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)