Dell PowerEdge M610x Başlangıç Kılavuzu - Sayfa 10

Anahtar Dell PowerEdge M610x için çevrimiçi göz atın veya pdf Başlangıç Kılavuzu indirin. Dell PowerEdge M610x 14 sayfaları. Dell poweredge blade servers getting started guide
Ayrıca Dell PowerEdge M610x için: Güncelleme Kılavuzu (44 sayfalar), Güncelleme Kılavuzu (21 sayfalar), Güncelleme Kılavuzu (14 sayfalar), Kurulum Kılavuzu (7 sayfalar), Başlangıç Kılavuzu (12 sayfalar), Başlangıç Kılavuzu (12 sayfalar), Portföy Kılavuzu (27 sayfalar), Teknik Kılavuz (48 sayfalar), Başlangıç Kılavuzu (12 sayfalar)

Dell PowerEdge M610x Başlangıç Kılavuzu
Power — Enclosure
Heat dissipation
NOTE: Heat dissipation is calculated using the
power supply wattage rating.
Maximum inrush current
System Voltage Requirements
NOTE: This system is also designed to be connected to
IT power systems with a phase to phase voltage not
exceeding 230 V.
DC/DC power supply (per power supply module)
Wattage
Connector
Heat dissipation
Maximum inrush current
System Voltage Requirements
NOTE: Heat dissipation is calculated using the power
supply wattage rating.
Physical — Blades
PowerEdge M915
Height
Width
Depth
Weight (maximum)
PowerEdge M910
Height
Width
Depth
Weight (maximum)
PowerEdge M820
Height
Width
10
1200 BTU/hr (maximum)
Under typical input voltage conditions and over the
entire system ambient operating range, the inrush
current may reach 55 A per power supply for 10 ms or
less.
16 A, 200 V AC to 240 V AC, 50 Hz/60 Hz (3000 W power
supply)
16 A, 100 V AC to 240 V AC, 50 Hz/60 Hz (2700 W power
supply)
2700 W
Molex # 394260002 at PSU end,
mating connector Molex # 39422-0012
1205 BTU/hr (maximum)
Under typical input voltage conditions and over the
entire system ambient operating range, the inrush
current may reach 120 A per power supply for 10 ms or
less.
75 A, 48 V DC to 60 V DC
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
12.7 kg (28 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)
48.6 cm (19.2 inch)
13.1 kg (29 lb)
38.5 cm (15.2 inch)
5 cm (2 inch)