Allmatic BIOS1 BRT Handbuch für die Installation - Seite 7
Blättern Sie online oder laden Sie pdf Handbuch für die Installation für Kontrolleinheit Allmatic BIOS1 BRT herunter. Allmatic BIOS1 BRT 12 Seiten. Programmable control board for barriers brt
7.2 Advanced menu:
MENU
PH2 multifunction input setting:
0 = Closing photocell
1 = Closing loop NO
2 = Closing loop NC
.
.
3 = Zone loop NO
4 = Zone and closing loop NO
5 = Loop for enable command OPEN
6 = Clock
Photocells test
0 = disabled
.
.
1 = enabled PHOTO1
2 = enabled PHOTO2
3 = enabled PHOTO1 and PHOTO2
Safety edge type
.
.
0 = contact (NC)
1 = resistive (8k2)
Safety edge test
.
.
0 = disabled
1 = enabled
.
.
Partial opening
PED multifunction input setting:
0 = Partial opening
1 = Closing loop NO
2 = Closing loop NC
3 = Zone loop NO
4 = Zone and closing loop NO
5 = Loop for enable command OPEN
6 = Clock
Blinker output mode
.
.
0 = Fix
1 = Blinking
.
.
Pre-flashing time (0 = disabled)
Courtesy ligth settings
0 = At the end of movement for a TCY time
1 = On if the barrier is not closed + TCY time
.
.
2 = On if courtesy light timer (TCY) not expired
3 = Open barrier light on/off
4 = Open barrier light with proportional flashing
.
.
Courtesy light time
Dead-man
.
.
0 = disabled
1 = enabled
Setting threshold of cycles for assistance request. Once limit is reached the next
.
.
cycles will be done with fast blinking (only if enabled) (0 = disabled)
Continuous blinking for assistance request (done only with closed gate).
.
.
0 = disabled
1 = enabled
Viewing of the memory location for a single transmitter
Cancellation of a single transmitter
Restore defaul settings, enter to modify the parameter and then keep pressed the
.
.
MENU button, a count down appears that ends with on the display
Cancelling all transmitters, enter to modify the parameter and then keep pressed
.
.
the MENU button, a count down appears that ends with on the display
6-1622245
rev.3
23/12/2016
DESCRIZIONE
ITA
ENG
FRA
VALORI IMPOSTABILI
ESP
DEU
POR
DEFAULT
min-max
0-6
0
0-3
0
0-1
0
0-1
0
0-100
30
0-6
0
0-1
1
0-10
0
0-4
3
0-900
0
0-1
0
0-100
0
0-1
0
0-999
0-999
UNITÀ
%
s
s
x1000
cicli
7 / 12