Miele PUR 68 W Betriebs- und Installationsanleitung - Seite 29

Blättern Sie online oder laden Sie pdf Betriebs- und Installationsanleitung für Lüftungshaube Miele PUR 68 W herunter. Miele PUR 68 W 40 Seiten. Ventilation system
Auch für Miele PUR 68 W: Betriebs- und Installationsanleitung (40 seiten), Betriebs- und Installationsanleitung (40 seiten), Betriebs- und Installationsanleitung (40 seiten), Betriebs- und Installationsanleitung (40 seiten), Betriebs- und Installationsanleitung (36 seiten)

Miele PUR 68 W Betriebs- und Installationsanleitung
a Exhaust air
b Recirculation
c Ventilation grille positioned at the top for recirculation
de Installation area (only d is required for recirculation mode). Wall or ceiling
area for the vent cut-out and for fitting the wall socket. For recirculation
mode, only a wall socket needs to be fitted.
Exhaust connection  150 mm

Safety distance (S)

The minimum distances between the cooking surface of a cooktop (pan
support(s) for gas models) and the bottom of the rangehood are as follows,
unless a greater distance is specified by the manufacturer of your cooking
appliance. See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater
than 45.4 MJ/h, but with a maximum of 77.8 MJ/h,
with no burner having a greater output than
17.3 MJ/h.
Multi-burner gas cooktop with total output greater
than 77.8 MJ/h, with a single burner having a
greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output
of 21.6 MJ/h.
Single burner gas cooktop with an output greater
than 21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater
than 29.2 MJ/h.
Installation
Minimum distance S
600 mm (AU, NZ)
450 mm
(HK, MY, SG, TH, TW)
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
29