Miele PUR 68 W Operating And Installation Instructions - Page 29

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele PUR 68 W. Miele PUR 68 W 40 pages. Ventilation system
Also for Miele PUR 68 W: Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (36 pages)

Miele PUR 68 W Operating And Installation Instructions
a Exhaust air
b Recirculation
c Ventilation grille positioned at the top for recirculation
de Installation area (only d is required for recirculation mode). Wall or ceiling
area for the vent cut-out and for fitting the wall socket. For recirculation
mode, only a wall socket needs to be fitted.
Exhaust connection  150 mm

Safety distance (S)

The minimum distances between the cooking surface of a cooktop (pan
support(s) for gas models) and the bottom of the rangehood are as follows,
unless a greater distance is specified by the manufacturer of your cooking
appliance. See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater
than 45.4 MJ/h, but with a maximum of 77.8 MJ/h,
with no burner having a greater output than
17.3 MJ/h.
Multi-burner gas cooktop with total output greater
than 77.8 MJ/h, with a single burner having a
greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output
of 21.6 MJ/h.
Single burner gas cooktop with an output greater
than 21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater
than 29.2 MJ/h.
Installation
Minimum distance S
600 mm (AU, NZ)
450 mm
(HK, MY, SG, TH, TW)
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
29