If the long screws are tightened insufficiently, it may cause of
the failure.
AirLeakage
Smudge
Dewing
Whenthereisstillagapevenaftertightening the long
screws firmly, readjust the height of the indoor unit.
No gap shall exist.
O
Donotturntheairlouverbyhand.
The louver mechanism would be damaged
.
Louver
NOTE
Without affecting the level of the indoor unit and the drainage pipe,
the height of the indoor unit body can be adjusted directly by using
the wrench from the corner hole of the panel even if the panel has
been tightened.
Wrench
*Please note that excessiveadjustmentofbodyheightmay
causewaterleakage fromdrainpan.
Step5
Please reinstall the corner plate (×4) after the installation of panel.
1) Please hang the binding tape at the inner side of the corner plate
by the panel grab as shown in the figure below.
2) Insert grab ①(×2) outside corner plate into the panel, and insert
grab ②(×1) inside corner plate into the panel.
Corner plate removal procedure upon completion of panel
installation:
Pull corner plate ① in the direction of arrow to remove it.