Note:
Setback (terminals 3 & 4): the input terminal controlled by remote; one terminal con-
nects to the internal power source with a 10K resistor, the other terminal connects to
the internal ground wire.
Relout (terminals 5 & 6): the output terminal controlled by remote; inside circuit is a OC
output, it can drive a relay that below 24V directly. The maximum drivable current is
30MA. The internal circuit is shown above.