Miller CST 282 Benutzerhandbuch - Seite 33

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schweißen System Miller CST 282 herunter. Miller CST 282 42 Seiten.

Miller CST 282 Benutzerhandbuch
7-4.

Troubleshooting

Trouble
Line Disconnect Open.
No weld output, unit
completely
Blown fuses.
Inoperative
Improper input connections.
Faulty output diode(s) D1 or D2 or D3
No weld output
Faulty HD1
Weld cables too small or defective.
Erratic or improper
weld output
Dirty or loose connections.
Blocked fan.
Fan not operating
Fan Failure
Complete Parts List is available at www.MillerWelds.com
Possible Causes
Remedy
Place line disconnect switch in On position. (See section
5-8 or 5-9)
Check and replace line fuses, if necessary, or reset circuit
breaker. (See section 5-8 or 5-9)
Check for proper input connections. (See section 5-8 or
5-9)
Check for shorts or opens in wiring.
Have factory authorized service agent check HD1.
Use proper size and type of weld cable. (See section 5-2)
Clean and tighten all weld cable connections. (See Sec-
tion 5-4)
Check for and remove anything blocking fan movement.
Have factory authorized service agent check fan motor.
OM-285986 Page 27