Aquanta Installation
Aquanta contains the electronics and sensor connections.
CAUTION:
Turn the electricity to the water heater off
by switching the circuit breaker to the "OFF" position.
This is typically a double breaker for electric water
heaters. Aquanta is intended for use on electrical branch-
circuits of 30 amps or less. Do not connect Aquanta to a
branch circuit that has a circuit breaker larger than 30
amps. The proper amperage of the circuit should be
determined by the labeled wattage of the water heater in accordance with the applicable
National and/or Local electrical codes. For installations requiring protective conduit
covering over the AC power conductors, use only flexible conduit covering. Do not attach
rigid conduit to Aquanta.
TIP: Test that the electricity is off at the water heater using a voltage tester.
1. Using a screwdriver, remove the electrical
cover plate from the top of the water heater.
Remove the wire nuts from the wires and
separate the wires. Remove the ground wire
from the ground screw. Loosen and remove
the cable clamp from the electrical cover plate
by loosening the nut on the underside of the
cover plate. Remove the cover plate from the
cable clamp and the AC Mains supply wires.