Miller TM-4414K Technisches Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Tragbarer Generator Miller TM-4414K herunter. Miller TM-4414K 36 Seiten.

2-1. Symbol Definitions

Circuit Breaker
Positive
Time

3-1. Description

This belt or hydraulically-driven generator supplies ac power to the platform to run tools through an ac receptacle,
and also operate lights, and cutting and welding equipment. All power regulation components are located in a water-
tight box that is connected by cable to the generator. The generator supplies power when running at the specified
speed with the Power switch on (switch is located on platform). A 3-pole, 30 Amp circuit breaker protects the generator
from overload.

3-2. Specifications

Drive-Type
Belt-Drive/Pulley
Hydraulic
TM-4414 Page 4
SECTION 2 − DEFINITIONS
Read Operator's
Manual
Negative
h
Hours
Welding Arc
(Electrode)
SECTION 3 − SPECIFICATIONS
Single-Phase, 6 kVA/kW, 25 A, 120/240 V,
1.0 Power Factor
100% Duty Cycle
Three-Phase 7.5 kVA/kW, 18 A,
240 V, 50/60 Hz,
1.0 Power Factor
100% Duty Cycle
A
Amperes
Alternating Current
(AC)
Temperature
Work Connection
Output
50/60 Hz
V
Volts
Output
Protective Earth
(Ground)
Voltage Input
803 233
Generator Speed
3000 rpm (50 Hz)
3600 rpm (60 Hz)
Belt/Hydraulic Drive Generator