AQUAPHOR RO-31 Benutzerhandbuch - Seite 6
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Water Filtration Systems AQUAPHOR RO-31 herunter. AQUAPHOR RO-31 12 Seiten. Drinking water machine
Auch für AQUAPHOR RO-31: Gebrauchsanweisung (17 seiten)
6. STARTING THE RO
To start the RO, it is necessary to connect the supply tubes and carry out the washing procedure of the
cartridges
Step 1 – Connect the delivery tubes according to fig. 2.
Blue tube – from the connection node to the inlet collector block fitting.
Blue tube – from the inlet fitting of the conditioning block to the inlet conditioning cartridge fitting
(if necessary, shorten the tube).
Red tube – from the saddle to the drain fitting of the collector block.
White tube – from the end of the clean water tip to the outlet fitting of the conditioning cartridge.
Figure 7a
Figure 7b
• For cartridge connection press the button and turn the cartridge counterclockwise (fig. 8b).
Step 3 – Flush the RO.
• Open the inlet valve;
• Insert the tip into the socket of the web clipper (fig. 14а), holding it above
the sink;
• Holding the tip with your hand , put the web clipper in the sink, drain the
water out from the water purifier for 10 minutes;
• Disconnect the tip from the web clipper by pressing the button located on
the slam end (fig. 14b);
• Close the inlet tap;
• Place the modules in the "For operation" position (see fig. 9);
• Open the inlet tap;
• Insert the hand piece into the slot of the storage container lid;
• Wait for the water to enter the storage tank and drain the water;
• Repeat this procedure 2 times.
6
How to connect the tubes (fig. 7a)
Remove the locking clip from the plastic sleeve. Insert
the pre-wetted end of the tube into the nozzle sleeve until
it stops at a depth of approximately 15 mm (0,6 inches) and
put the locking clip back .
Check the strength of fixing the tube: with a force of
8–10 kgf (78,4–98 N) the tube should not be pulled out.
How to disconnect the tubes (fig. 7b)
To disconnect the tubes pull the locking clip out from
the plastic sleeve by pushing the butt of the plastic sleeve,
then pull the tube.
Step 2 – Install the filter cartridges.
•
Remove thermostatic tape and transporting plugs from
the cartridges.
•
Make sure, that the inside surfaces of the subunit flange
cartridges are clean (no coal dust, debris, etc.). If there is
any dust, flush it under water.
•
According to the (fig. 9) "the position of the cartridges In
the RO", install the cartridges in the position "for
flushing". For this insert the cartridge up to the stop to
the appropriate collector and turn it in a clockwise
direction until you hear a click (fig. 8а).
Figure 8a
Figure 8b