AquaPRO 03AP548 Anleitung Handbuch - Seite 7

Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Water Filtration Systems AquaPRO 03AP548 herunter. AquaPRO 03AP548 16 Seiten. Pressure filter/uv clarifier

AquaPRO 03AP548 Anleitung Handbuch
REPLACING THE UV GLOBE
Replacement UV Globes can be purchased from your local stockist or ordered from Aquatec Equipment.
• Turn off power supply to the filter and remove plug
from power outlet. Turn off your water pump.
• Undo the 4 screws on the top of the filter holding the
UV-C Assembly in place.
• Carefully lift up the UV•C Assembly out of the filter lid.
Take care not to impact the quartz sleeve on anything
- it will break.
• Undo the quartz sleeve locking nut at the top of the
quartz sleeve. Take care not to lose the quartz sleeve O'
ring and collar.
• Carefully remove the quartz sleeve from the UV•C.
assembly. Clean the Quartz sleeve to remove any algae
or lime scale build-up. Place in a secure position.
• You can now access the globe to replace it. Pull out the
old globe and discard responsibly. Insert a new globe
ensuring it is connected securely.
• Replace the quartz sleeve onto the UV•C assembly
ensuring the O-rings and collar is located properly.
Replace and tighten the quartz sleeve locking nut.
• Replace the UV-C assembly into the top of the filter
ensuring it fits securely. Tighten the 4 screws fixing the
assembly into the filler lid.
• Turn your water pump back on, and then reconnect
power supply, and turn on your filter. You have
successfully replaced your UV-C globe .
AQP AP2100UV Instructions.indd 7
AP2100UV / AP5000UV / AP10000UV
PRESSURE FILTER / UV CLARIFIERS
A Q U A T E C E Q U I P M E N T . C O M
27/10/16 7:53 am