8
Insert Filters
1. Insert the Pre-Filter into the first housing labeled "Pre-Filter". Insert the
Iron Filter into the housing labeled "Iron-Filter".
NOTE: The notch in the bottom of the housing centers the filter cartridges.
2. Coat the O-rings of both filter housings with the included lubricant.
3. Manually tighten the housings to the
sump caps, and then use the provided
sump wrench to tighten the housings.
9
Final System Check
Once installation is complete, allow proper time for glue to dry
according to manufacturer instructions. Then, slowly turn on main
water supply. Once system has fully pressurized, inspect for leaks.
After inspecting for leaks, turn on the faucet closest to the
installed unit and allow water to run for 2 minutes for the final
flushing period.
Malfunction
Leaks between housing
sump and housing head.
Leaks in inlet/outlet
connections.
Troubleshooting Guide
Cause
a. Housing not sufficiently
tightened.
b. O-ring affected/old.
a. Not enough sealant
and/or connection not
sufficiently tightened.
b. Improper connection
type.
INSTALLATION STEPS
NOTE: You should only need
to use the wrench for a ⅛ to a
¼ of a turn with the wrench.
Remedy
a. Tighten the housing
further with the wrench.
b. If the housing still leaks,
change the housing's
O-ring with a new one.
a. Remove the previously
applied plumbers tape
and re-apply plumbers'
tape. Tighten the
connection properly.
b. Only use NPT tapered
fittings.
9