WARNINGS
•
The Coupling Tool BCB 110 is supplied with a pair of reusable elastomer expanders for each
processing diameter, from ø 40 to 90 mm. After about 5-10 flarings, depending on the dia-
meter, the elastomer expander may struggle to enter into the pipe due to excessive expan-
sion.This does NOT mean that it is exhausted: the elastomer expander returns to its original
shape after a rest period depending on the working temperature. In the meantime, set the
machine out of work and replace the elastomer with the supplied second one, to proceed
working.
•
At temperatures closed to 0°C, the return time of the expander can be considerably longer.
•
Discard the elastomer only in case of breakage or if it doesn't go back to its initial shape
after the rest period.
MAINTENANCE
• In order to clean the equipment, use a cloth slightly soacked with a common, non aggres-
sive detergent. DO NOT USE acid substances, thinners, solvents, and powdered products
which may damage its components.
• The BCB 110 Tool is equipped with a display that warns, both acoustically and visually, of
the approaching scheduled maintenance time. The periodic check is necessary to preserve
the good functioning of the equipment.
• Any servicing work on the Coupling Tool BCB 110 shall be performed at Aquatechnik me-
chanical dept. Any alteration of the equipment or its components involve the cancellation of
the warranty.
• In case of consistent loss of oil from the equipment, send immediately the Coupling Tool
BCB 110 to Aquatechnik mechanical dept. for subsequent inspection and repairing. (War-
ning: avoid that leaked oil comes into contact with the eyes or skin. Do not inhale or ingest.
Do not disperse into the environment).
• Avoid that the equipment get wet; water and liquids in general can damage the electrical
circuits.
• Warning: During maintenance operations, make sure that the equipment is disconnected
from power sources (battery).