IV. Diagnostics/Indication of Errors
In the display of the control system certain combinations of letters and
numbers are shown to indicate the status of the control system. This
facilitates adjustments and helps to locate errors.
Error
Meaning
Code
RES
Press the RESET button on
the casing.
ALA
Alarm
SC
Short circuit in the power
supply of the motor
SCE
Short circuit in the power
supply of the magnet
S-1
STOP 1 active
S-2
STOP 2 active
S-3
STOP 3 active
T01
Error due to too long
operating time
Continuation on the next page
Technical Manual E8
Possible Causes /
Measures
In general a RESET is required to restart
the control system after switching on the
current or after an alarm.
PLEASE NOTE: As long as the alarm is
still active (check smoke detector or
release button), the RESET will not work.
In case the gate has not been closed
completely after an alarm: Turn off the
current and switch it on again, wait till
the gate has closed completely and then
press RESET.
One or several smoke detectors have
set off.
In case the light barrier is connected
here: please check if anything is in its
survey area.
Please check which maximum operating
time has been adjusted (adjustable bet-
ween 3 and 30 minutes, parameter P-
E). Normally this error occurs whenever
the current supply of the gate operator
is interrupted or the movement of the
gate is obstructed.
Press RESET button (after the current
supply has been restored). Now the
control system is ready to work again.