Para-
Function
meter
P-0
Position of the door
Indicates the present position of the door.
Has just informative character. After the adjustment of the other
parameters the display always returns to P-0
P-1
Crawling speed
This speed is activated upon reaching the memorized position
or the limit switches „Crawling speed"; the door moves with
the adjusted slower speed until reaching its final positions
P-2
Normal Opening speed
P-3
Function of the STOP-switches 2 and 3 in alarm
000: STOP 2 and STOP 3 also active during an alarm closing
001: STOP 2 and STOP 3 without function during an alarm closing
(Closing function has priority in case of alarm.)
P-4
Blocking of the door in the closed position
000: Door is blocked in the closed position
001: Door is not blocked in the closed position
P-5
Automatic closing
000: Automatic closing switched off
001 - 180: Automatic closing ON. Value indicates time in sec.
P-C
Closing: must be adjusted to the value 000
000: Closing with counterweight (FOR FIRE PROTECTION)
001: CLosing with motor: 24/48 VDC motors
002: CLosing with motor: three-phase AC motors
P-d
„Release function". Must be adjusted to 000
Press simultanously to get to P-6 to P-b
P-6
RESET position control / Position „Door CLOSED"
Adjust to 000, when the door is completely closed.
P-7
Position „Door OPEN" (with position control)
Move door with the OPEN switch to the Position OPEN. Enter the
value shown in P-0 in P-7.
P-8
Position „Creep speed OPEN" (with position control)
Adjusted value must be lower than P-7 (recommendation: about
40 - 50 digits below P-7). Move door with the OPEN switch to
position „Crawling speed OPEN". Enter the value shown in P-0
P-9
Position „Creep speed CLOSE" (with position control)
Adjusted value must be higher than P-6. Move door with switch to
position „Crawling speed CLOSE". Enter the value shown in P-0 in P- 9.
P-A
Function STOP 3 (safety element)
000: Door stops and continues closing when free again
001: Door stops and then opens completely again
P-b
Position control integrated in drive unit/limit switches
000: Position control with position control system
001: Position control with separate limit switches
Page 05.023.14
III. Adjustment / Programming (cont.)
© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200703
Possible
ex works
adjustments
not adjustable
-
040 - 100
040
100 - 200
150
000 - 001
001
000 - 001
001
000 - 180
000
000 - 002
001
000 - 001
000
000 - 999
000
000 - 999
000
000 - 999
000
000 - 999
015
000 - 001
001
000 - 001
001
Your value
-
000
000