Olympus BX41 Anleitung Handbuch - Seite 26
Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Mikroskop Olympus BX41 herunter. Olympus BX41 34 Seiten. System microscope
Auch für Olympus BX41: Anleitung Handbuch (36 seiten)
OPTICAL CHARACTERISTICS
The following table shows the optical characteristics of com-
binations of eyepieces and objectives. The figure on the right
shows the performance data engraved on the objectives.
NOTE
Refer to the latest catalogue or consult your local Olympus
representative for the updated information on the eyepieces
and objectives that can be combined with this microscope.
Optical
character
Magni-
fication
Objective
AchC Achromat*
4X
10X
(FN20)
40X
100X
* Be sure to use the AchC series in combination with the WHC10X.
Optical
character
Magni-
fication
Objective
Ach/Ach-P
10X
Achromat/Achromat
20X
for Polarized Light
40X
(FN 22)
60X
· 60X and 100XOI
100XO
are only available
100XOI 0.60-1.25
with Ach.
Plan/Plan-P
4X
Plan Achromat/
10X
Plan Achromat for
10XCY
Polarized Light
20X
(FN 22)
40X
·
Plan-P has 4X only.
50XOI 0.50-0.90
100XO
UPlan-Fl/UPlan Fl-P
Universal Semi-
4X
Apochromat/
10X
Universal Plan
20X
Semi-Apochromat
40X
for Polarized Light
60XOI 0.65-1.25
(FN26.5)
100XO
· 60X OI and 100X OI
100XOI 0.60-1.30
are only available
with UPlan Fl.
UPlan Apo
4X
Universal Plan
10X
Apochromat
20X
(FN26.5)
40X
40XOI
0.5-1.00
60X
100XOI
0.5-1.35
Plan Apo
1.25X
Plan Apochromat
2X
(FN26.5)
40X
60XO
100XO
UMPlan Fl
No Cover
Universal Plan
40X
Semi-Apochromat
(FN26.5)
Cover
Reso-
glass
W.D.
lution
N.A.
thick-
(mm)
(µm)
ness
0.10
28.90
—
3.4
0.25
6.30
0.17
1.34
0.65
0.62
0.17
0.52
1.30
0.20
—
0.26
Cover
Reso-
glass
W.D.
N.A.
lution
thick-
(mm)
(µm)
ness
0.25
6.1
—
1.34
0.40
3.0
—
0.84
0.65
0.45
0.17
0.52
0.80
0.15
0.17
0.42
1.25
0.13
—
0.27
0.13
-
0.27
0.10
22.0
—
3.36
0.25
10.5
—
1.34
0.25
10.5
—
1.34
0.40
1.2
0.17
0.84
0.65
0.56
0.17
0.52
0.20
—
0.37
1.25
0.15
—
0.27
0.13
17.0
—
2.58
0.30
10.0
—
1.12
0.50
1.6
0.17
0.67
0.75
0.51
0.17
0.45
0.10
0.17
0.27
1.30
0.10
0.17
0.26
0.10
0.17
0.26
0.16
13.0
—
2.1
0.40
3.1
0.17
0.84
0.70
0.65
0.17
0.48
0.85
0.2
0.11-0.23
0.39
0.12
-
0.34
0.90
0.20
0.11-0.23
0.37
0.10
0.17
0.25
0.04
5.1
—
8.38
0.08
6.0
—
4.19
0.95
0.14
0.11-0.23
0.35
1.40
0.10
0.17
0.24
1.40
0.10
0.17
0.24
0.75
0.63
0
0.45
Magnification
Mechanical tube length
Eyepiece
WHC10X (FN20)
Depth of focus
Total mag.
(µm)
40X
175
100X
28.0
400X
3.0
1000X
0.66
Indicates the objective is provided with a correction collar.
Eyepiece
WH10X (FN22)
Depth
Total
Field
Total
of focus
mag.
of view
mag.
(µm)
100X
28.0
2.2
150X
200X
6.09
1.1
300X
400X
3.04
0.55
600X
600X
1.76
0.37
900X
1000X
0.69
0.22
1500X
1000X
0.69
0.22
1500X
40X
175
5.5
100X
28.0
2.2
150X
100X
28.0
2.2
150X
200X
6.09
1.1
300X
400X
3.04
0.55
600X
500X
1.75
0.44
750X
1000X
0.69
0.22
1500X
40X
127
5.5
100X
22.4
2.2
150X
200X
7.00
1.1
300X
400X
2.52
0.55
600X
600X
0.98
0.37
900X
1000X
0.66
0.22
1500X
1000X
0.66
0.22
1500X
40X
99.5
5.5
100X
15.9
2.2
150X
200X
4.65
1.1
300X
400X
2.14
0.55
600X
400X
1.70
0.55
600X
600X
1.50
0.37
900X
1000X
0.62
0.22
1500X
12.5X
872
17.6
18.75X
20X
398
11.0
400X
1.86
0.55
600X
600X
0.85
0.37
900X
1000X
0.59
0.22
1500X
400X
1.66
0.55
600X
BX41
Name
Numerical aperture
Cover glass thickness
Remark
Field of view
5.0
2.0
0.5
0.2
WH15X (FN14)
Remark
Depth
Field
of focus
of view
(µm)
20.9
1.4
4.64
0.7
2.35
0.35
1.39
0.23
0.55
0.14
Iris
0.55
0.14
60X
85.8
3.5
20.9
1.4
20.9
1.4
ND filter
4.64
0.7
2.35
0.35
1.30
0.28
Iris
0.55
0.14
60X
92.9
3.5
16.5
1.4
5.22
0.7
1.93
0.35
0.60
0.23
Iris
0.52
0.14
Iris
0.52
0.14
60X
71.7
3.5
11.5
1.4
3.39
0.7
1.62
0.35
1.30
0.35
Iris
1.17
0.23
0.49
0.14
Iris
639
11.2
30X
287
7.0
1.40
0.35
0.64
0.23
Iris
0.47
0.14
1.27
0.35
24