TIP:
If the Display Does Not Scroll As Expected
When power is first applied, the unit should quickly go through startup
and begin cycling through the pre-programmed display items. If the
display does not scroll after startup and/or looks similar to the following:
(Part numbers are for example only)
µ
6200
FLO Boot Prom
2100917-001 (COPYRIGHT)
Disconnect the main power and then re-connect it. You should see
something similar to:
Verifying Flash
or
COLD BOOT
XXXXX
Flash 2100917-001
µ
Checksum = XXXX
6213
FLO Flash
Verify Passed
2100917-001 (COPYRIGHT)
If the display still doesn't scroll, try disconnecting the power and re-
connecting it again. If still no success, do the following:
With PCCU32, connect to the unit and establish communications such as
Connect To Totalflow, Entry Mode, etc. Go into Terminal Mode and type
"0.0.0=COLD" (Do not enter quotes). The unit should go through a Cold
Start procedure and then begin scrolling. If this does not succeed, call
the number on the back of this guide and talk to a customer service
representative.
19