Con guring the DiGidot C4

To start using the DiGidot C4 as intended meaning to
start controlling LED lights first the device should be
configured. Initial configuration includes naming the
DiGidot C4, giving it an IP address and Subnet mask
which the Art-Net software/device will recognize. Last
step is to configure the number of universes and the
type of LEDs that you will use it with.
To configure the device you go to Settings. From there
you can change the IP address and subnet mask of the
DiGidot C4. The IP must always start with 10, for your
computer to recognize it. The Subnet Mask should
always stay 255.0.0.0.
Note that those are default settings for working with
the DiGidot C4. Alternatively the DiGidot can match
your local network settings to work in your network
e.g. 192.168.x.x (be sure to update your own network
to match the DiGidot C4 Network settings)
Once the device is named and given a recognizable IP
address the next step is to configure the amount of
universes and the type of LED they will be used with.
From the button 'Select an output' you can choose
the type of LED source the DiGidot C4 will be used
with. Then the number of universes used can be
adjusted.
Configuring the type of LED that will be used with the
DiGidot C4 will then allow you to connect your LED
lights or DMX512 properly to the DiGidot C4. On the
next page the meaning of each of the outputs on the
DiGidot C4 is displayed and how they vary depending
on the type of output that is used.