Cisco Catalyst 9130AX Series Handbuch "Erste Schritte - Seite 27
Blättern Sie online oder laden Sie pdf Handbuch "Erste Schritte für Drahtloser Zugangspunkt Cisco Catalyst 9130AX Series herunter. Cisco Catalyst 9130AX Series 49 Seiten.
Cisco Catalyst 9130AX Series Access Points
Figure 16
Locking the AP to the Bracket
Position of the hasps for the locks on the back of the AP
1
1 0
Grounding the Access Point
W arning
Only trained and qualified personnel should be allow ed to install, replace, or service this equipment.
Statement 1030
Grounding is not required for indoor installations. However, while using the C9130AXE AP model, if the external antenna
is placed outdoors, you must connect the outdoor antenna cable to a lightning arrestor and connect the lightning arrestor
to ground.
For supported external antennas, see
The outdoor antenna connection must be grounded in accordance with the ANSI/NFPA 70, the National Electrical code
(NEC), Article 800, Grounding of Outer Conductive Shield of a Coaxial Cable.
W arning
To reduce the risk of electric shock, the shield of the coaxial cable must be connected to the building
earth. Statement 1253
"List of External Antennas Supported on
27
C9130AXE".