ACU-RITE SENC 150 Anleitung Handbuch - Seite 5

Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Messgeräte ACU-RITE SENC 150 herunter. ACU-RITE SENC 150 12 Seiten. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Auch für ACU-RITE SENC 150: Installationshandbuch (8 seiten), Referenzhandbuch (20 seiten), Installationshandbuch (4 seiten), Installationshandbuch (6 seiten)

SENC 150 Reading Head Replacement Instructions

Preparing the removal

 Remove all cable ties or retaining clips.
 Disconnect the reading head cable from the readout.
Installing alignment brackets
 Attach the alignment brackets (included in head replacement
hardware kit) by inserting the top ears into the bottom grooves
in the scale case.
 Numbers and letters on reading head casting and alignment
brackets correspond when assembled.
Slide brackets against
reading head snap into place.
2 Preparing the removal
Insert brackets at 45°
and twist to lock in scale grove.
5