ACU-RITE ENC 250 Anweisungen für die Ersetzung - Seite 2

Blättern Sie online oder laden Sie pdf Anweisungen für die Ersetzung für Medienkonverter ACU-RITE ENC 250 herunter. ACU-RITE ENC 250 2 Seiten. Linear encoder reading head
Auch für ACU-RITE ENC 250: Referenzhandbuch (13 seiten)

ACU-RITE
Twist bracket
Slide brackets back
45°
away from the
reading head and
cable
Slide alignment brackets away from the reading
head.
Remove brackets and save.
Positioning tool
Hold tool securely so that there is no gap between
the scale case extrusion sections.
Use caution when sliding the reading head into
the scale case. Carefully slide the head to the
center section of the encoder.
ONE PRECISION WAY • MASON INDUSTRIAL PARK • JAMESTOWN, NEW YORK 14701
P.N. 104000-365
®
Twist bracket
45°
Left hand end of
scale case
ACU-RITE
Reading Head Replacement Instructions
Reinstall alignment brackets using the reverse
order of prior removal.
Slide the reading head with the brackets attached
to the mounting bracket location. Align the
reading head and bracket mounting holes. If the
bracket was moved from its original position, it
must be realigned to the reading head while
attached to the alignment brackets.
Attach the reading head with the two 8-32 SHCS,
but do not tighten.
Set each leveling screw by placing a .001 - .003"
feeler gage between the screw and reading head
mounting bracket, and adjust each screw until a
slight drag is felt on the feeler gage.
Evenly tighten the two 8-32 SHCS to secure
the reading head in place.
Completing the installation ...
Remove the alignment brackets and replacement
reading head scale section. Reinstall left end cap.
Tighten screws securely to compress the end cap
gasket.
Repackage the defective reading head in the same
manner as it was received. Use the return
information provided for returning the head to
ACU-RITE.
®
2
ENC 250 Linear Encoder
Leveling screws (3)
Edition B